Acoustic parameters
In the different WPS scripts of NoiseModelling, you will find many input parameters, mandatory or optional.
Below we list the most important ones, indicating, where necessary, the default values and those we recommend (from an acoustic point of view).
The following parameters may be found in the scripts dealing with noise emission or propagation (e.g Noise_level_from_traffic, Noise_level_from_source`, …)
Probability of occurrences
Parameter name:
confFavorableOccurrencesXXXXX(withXXXXX= evening, day, night, …)Description: Comma-delimited string containing the probability ([0,1]) of occurrences of favourable propagation conditions. Follow the clockwise direction. The north slice is the last array index (n°16 in the schema below) not the first one
Type: Double
Default value:
0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5, 0.5Recommanded value:
Relative humidity
Parameter name:
confHumidityDescription: Humidity for noise propagation (%) [0,100]
Type: Double
Default value:
70Recommanded value: depends on the average conditions at the location where you perform the simulation
Air temperature
Parameter name:
confTemperatureDescription: Air temperature (°C)
Type: Double
Default value:
15Recommanded value: depends on the average conditions at the location where you perform the simulation
Order of reflexion
Parameter name:
confReflOrderDescription: Maximum number of reflections to be taken into account. Warning: adding 1 order increases the processing time significantly
Type: Integer
Default value:
1Recommanded value:
1or2
Diffraction on horizontal edges
Parameter name:
confDiffHorizontalDescription: Compute or not the diffraction on horizontal edges
Type: Boolean
Default value:
FalseRecommanded value:
True
Diffraction on vertical edges
Parameter name:
confDiffVerticalDescription: Compute or not the diffraction on vertical edges. Following Directive 2015/996, enable this option for rail and industrial sources only
Type: Boolean
Default value:
FalseRecommanded value:
Maximum source-receiver distance
Parameter name:
confMaxSrcDistDescription: Maximum distance between source and receiver (meters)
Type: Double
Default value:
150Recommanded value: Between
500and800
Maximum source-reflexion distance
Parameter name:
confMaxReflDistDescription: Maximum search distance of walls / facades from the “Source-Receiver” segment, for the calculation of specular reflections (meters)
Type: Double
Default value:
50Recommanded value: Between
350and800
Wall absorption coefficient
Parameter name:
paramWallAlphaDescription: Wall absorption coefficient [0,1] (between
0: “fully absorbent” and1: “fully reflective”)Type: Double
Default value:
0.1Recommanded value:
0.1
Separate receiver level by source identifier
Parameter name:
confExportSourceIdDescription: Keep source identifier in output in order to get noise contribution of each noise source
Type: Boolean
Default value:
FalseRecommanded value:
Thread number
Parameter name:
confThreadNumberDescription: Number of thread to use on the computer
Type: Integer
Default value:
0(0= Automatic. Will check the number of cores and apply -1. (e.g: 8 cores = 7 cores will be used))Recommanded value:
0